Accuracy and efficiency of an artificial intelligence-based pulmonary broncho-vascular three-dimensional reconstruction system supporting thoracic surgery: retrospective and prospective validation study

基于人工智能的肺支气管血管三维重建系统在胸外科手术中的准确性和效率:回顾性和前瞻性验证研究

阅读:1

Abstract

BACKGROUND: Anthropomorphic phantoms are used in surgical planning and intervention. Ideal accuracy and high efficiency are prerequisites for its clinical application. We aimed to develop a fully automated artificial intelligence-based three-dimensional (3D) reconstruction system (AI system) to assist thoracic surgery and to determine its accuracy, efficiency, and safety for clinical use. METHODS: This AI system was developed based on a 3D convolutional neural network (CNN) and optimized by gradient descent after training with 500 cases, achieving a Dice coefficient of 89.2%. Accuracy was verified by comparing virtual structures predicted by the AI system with anatomical structures of patients in retrospective (n = 113) and prospective cohorts (n = 139) who underwent lobectomy or segmentectomy at the Peking University Cancer Hospital. Operation time and blood loss were compared between the retrospective cohort (without AI assistance) and prospective cohort (with AI assistance) for safety evaluation. The time consumption for reconstruction and the quality score were compared between the AI system and manual reconstruction software (Mimics®) for efficiency validation. This study was registered at https://www.chictr.org.cn as ChiCTR2100050985. FINDINGS: The AI system reconstructed 13,608 pulmonary segmental branches from retrospective and prospective cohorts, and 1573 branches of interest corresponding to phantoms were detectable during the operation for verification, achieving 100% and 97% accuracy for segmental bronchi, 97.2% and 99.1% for segmental arteries, and 93.2% and 98.8% for segmental veins, respectively. With the assistance of the AI system, the operation time was shortened by 24.5 min for lobectomy (p < 0.001) and 20 min for segmentectomy (p = 0.007). Compared to Mimics®, the AI system reduced the model reconstruction time by 14.2 min (p < 0.001), and it also outperformed Mimics® in model quality scores (p < 0.001). INTERPRETATION: The AI system can accurately predict thoracic anatomical structures with higher efficiency than manual reconstruction software. Constant optimization and larger population validation are required. FUNDING: This study was funded by the Beijing Natural Science Foundation (No. L222020) and other sources.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。