A case report of an arthroscopic-assisted fixation of a small Hoffa fracture in a young patient

一例年轻患者小霍夫骨折关节镜辅助固定术的病例报告

阅读:1

Abstract

INTRODUCTION: Hoffa fracture is a type of rare tangential supracondylar distal femoral fracture. The most common mechanism of this fracture injury is high energy trauma. In some cases, its poor visibility on X-rays makes its diagnosis difficult and needs more than routine X-rays. Treatment methods include conventional ORIF, or arthroscopy-assisted fixation as a more challenging method. CASE REPORT: We present a case of a young female patient who sustained a low energy injury trauma to her left knee, which caused in a small minimally displaced lateral unicondylar Hoffa fracture. DISCUSSION: Although it needs more experience and special tools, arthroscopy-assisted fixation of Hoffa fracture provides a good method of treatment, and it has many advantages over open method. CONCLUSION: Our aim here is to confirm that Hoffa fracture may occur even with low energy knee trauma, and that arthroscopy-assisted fixation is a successful, applicable and alternative method to ORIF for small and thin osteochondral fragments, and could provide good stability and union even when using only one screw for fixation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。