Q-value customized versus wavefront-optimized ablation in femtosecond laser-assisted LASIK for myopia and myopic astigmatism: a prospective contralateral comparative study

飞秒激光辅助LASIK治疗近视和近视散光中Q值定制消融与波前优化消融的比较:一项前瞻性对侧对照研究

阅读:1

Abstract

BACKGROUND: Corneal refractive surgery for myopia results in an oblate shift with increased postoperative aberrations inversely affecting the quality of vision. Aspheric ablation profiles have been introduced to minimize such a problem. The aim of this study was to compare changes in corneal asphericity, central and mid-peripheral pachymetry between the Q-value customized and the wavefront-optimized (WFO) ablation profiles. METHODS: A prospective, comparative non-randomized fellow eye study was conducted. Eighty eyes of 40 eligible patients underwent femtosecond laser-assisted laser in situ keratomileusis for myopia and myopic astigmatism. In each patient, the more myopic eye was included in the custom-Q ablation experimental group and the other less myopic eye was included in the WFO control group. For the custom-Q group, the target asphericity was set to the preoperative Q-value. Corneal asphericity, central and mid-peripheral pachymetric changes and the root mean square of corneal higher-order aberrations (RMSh) were assessed 6 months following surgery. Visual and refractive outcomes were also evaluated in both platforms 6 months postoperatively. RESULTS: The mean preoperative refractive spherical equivalent was significantly more myopic in the custom-Q group than in the WFO group (P = 0.001). The mean Q-value changed from - 0.2 ± 0.1 to 0.6 ± 0.7 and from - 0.2 ± 0.1 to 0.4 ± 0.5 in the custom-Q and WFO groups, respectively. The oblate shift in corneal asphericity was not significantly different between both treatment groups (P = 0.094). The mean ablation depth at the pupillary center was significantly greater in the custom-Q group (P = 0.011), while there was no significant difference at the mid-peripheral pachymetry (P = 0.256). The RMSh significantly increased in both treatment profiles (P < 0.001) with no significant difference between the two groups (P = 0.06). The uncorrected distance visual acuity (UDVA) and the manifest refraction spherical equivalents (MRSE) significantly improved in both treatment groups (P < 0.001). CONCLUSIONS: The custom-Q treatment profile with target asphericity set at the preoperative Q-value achieved comparable outcomes vs. the WFO profile in terms of postoperative corneal asphericity and mid-peripheral pachymetry despite the greater amount of ablation, the smaller optical zone, and the resulting increase in postoperative corneal flattening in the custom-Q group. Trial registration (Clinicaltrials.gov): NCT04738903, 4 February 2021- Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04738903.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。