Repositioning a posteriorly dislocated silicone plate-haptic toric intraocular lens

复位后脱位的硅胶板袢式散光人工晶状体

阅读:1

Abstract

We describe a technique for repositioning an encapsulated, posteriorly dislocated silicone plate-haptic toric intraocular lens (IOL) while preventing further dislocation into the vitreous cavity. Sutures of 10-0 polypropylene were used to ensure safe retrieval of the dislocated IOL. An anterior vitrectomy was then performed to remove the contracted capsular bag around the IOL. The IOL fixation hole was temporarily externalized to allow quick and secure IOL fixation, eliminating the risk for losing the slippery silicone IOL into the vitreous cavity. Using this technique, the IOL was successfully placed in the proper position and resulted in good vision for the patient while avoiding the trauma of lens exchange.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。