Carotid Stenting without Embolic Protection Increases Major Adverse Events: Analysis of the National Surgical Quality Improvement Program

未采取栓塞保护措施的颈动脉支架置入术会增加重大不良事件的发生率:国家外科质量改进计划分析

阅读:1

Abstract

BACKGROUND AND PURPOSE: Published data regarding embolic protection device efficacy is mixed, and its use during carotid artery stent placement remains variable. We, therefore, examined the frequency of embolic protection device use and its association with outcomes after carotid artery stent placement using a national quality improvement data base. MATERIALS AND METHODS: Patients undergoing carotid artery stent placement with or without embolic protection devices were identified in the American College of Surgeons National Surgical Quality Improvement Program data base. The primary outcome was the incidence of major adverse cardiovascular events (defined as death, stroke, or myocardial infarction/arrhythmia) within 30 days. Propensity scoring was used to create 2 matching cohorts of patients using demographic and baseline variables. RESULTS: Between 2011 and 2018, among 1200 adult patients undergoing carotid artery stent placement, 23.8% did not have embolic protection devices. There was no trend toward increased embolic protection device use with time. Patients without embolic protection device use received preoperative antiplatelets less frequently (90.6% versus 94.6%, P = .02), underwent more emergent carotid artery stent placement (7.2% versus 3.6%, P = .01), and had a higher incidence of major adverse cardiovascular events (OR = 1.81; 95% CI, 1.11-2.94) and stroke (OR = 3.31; 95% CI, 1.71-6.39). After compensating for baseline imbalances using propensity-matched cohorts (n = 261 for both), carotid artery stent placement without an embolic protection device remained associated with increased major adverse cardiovascular events (9.2% versus 4.2%; OR = 2.30; 95% CI, 1.10-4.80) and stroke (6.5% versus 1.5%; OR = 4.48; 95% CI, 1.49-13.49). CONCLUSIONS: Lack of embolic protection device use during carotid artery stent placement is associated with a 4-fold increase in the likelihood of perioperative stroke. Nevertheless, nearly one-quarter of patients in the American College of Surgeons National Surgical Quality Improvement Program underwent unprotected carotid artery stent placement. Efforts targeting improved embolic protection device use during carotid artery stent placement are warranted.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。