Fiber Optic-Based Thermal Integrity Profiling of Drilled Shaft: Inverse Modeling for Spiral Fiber Deployment Strategy

基于光纤的钻孔桩热完整性分析:螺旋光纤部署策略的逆向建模

阅读:1

Abstract

The current state of practice to interpret the thermal integrity profiling (TIP) data of drilled shaft is the so-called effective radius method. It uses the concrete pouring log and average temperature to construct a relationship between temperature distribution and effective radius that can be used to reconstruct a drilled shaft model. While this effective radius method is computationally inexpensive and has good operationality, it is not good at predicting the dimensions and shape of shaft defects. Upgrading the sensor used in conventional TIP from thermocouples/thermal wires to fiber optic sensors, the spatial resolution of the measured temperature will be enhanced. By using the newly proposed spiral fiber deployment strategy, we can improve the reconstruction of shaft defects in the integrity testing of drilled shafts. The corresponding inverse modeling of defected shaft reconstruction for spiral deployment is proposed in this paper based on the temperature distribution pattern that is learned from forward modeling. Through inverse modeling, the details of defects in drilled shafts can be reconstructed numerically. An analysis of the results shows that the prediction by inverse modeling has good agreement with the forward modeling set up initially. This work helps the evolution of the TIP from the nondestructive testing stage to the quantitative nondestructive evaluation stage.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。