Potential Application of Pin-to-Liquid Dielectric Barrier Discharge Structure in Decomposing Aqueous Phosphorus Compounds for Monitoring Water Quality

针对液介质阻挡放电结构在分解水中磷化合物监测水质中的潜在应用

阅读:8
作者:Gyu Tae Bae, Jae Young Kim, Do Yeob Kim, Eun Young Jung, Hyo Jun Jang, Choon-Sang Park, Hyeseung Jang, Dong Ho Lee, Hyung-Kun Lee, Heung-Sik Tae

Abstract

Here, we proposed a pin-to-liquid dielectric barrier discharge (DBD) structure that used a water-containing vessel body as a dielectric barrier for the stable and effective treatment of aqueous solutions in an open atmosphere. To obtain an intense pin-to-liquid alternating current discharge using a dielectric barrier, discharge characteristics, including the area and shape of a ground-plate-type electrode, were investigated after filling the vessel with equivalent amounts of water. Consequently, as the area of the ground electrode increased, the discharge current became stronger, and its timing became faster. Moreover, we proposed that the pin-to-liquid DBD reactor could be used to decompose phosphorus compounds in water in the form of phosphate as a promising pretreatment method for monitoring total phosphorus in water. The decomposition of phosphorus compounds using the pin-to-liquid DBD reactor demonstrated excellent performance-comparable to the thermochemical pretreatment method-which could be a standard pretreatment method for decomposing phosphorus compounds in water.