Patient adherence to and tolerability of self-administered interferon β-1a using an electronic autoinjection device: a multicentre, open-label, phase IV study

患者使用电子自动注射装置自行注射干扰素β-1a的依从性和耐受性:一项多中心、开放标签的IV期研究

阅读:1

Abstract

BACKGROUND: Achieving good adherence to self-injected treatments for multiple sclerosis can be difficult. Injection devices may help to overcome some of the injection-related barriers to adherence that can be experienced by patients. We sought to assess short-term adherence to, and tolerability of, interferon (IFN) β-1a administered via electronic autoinjection device in patients with relapsing-remitting multiple sclerosis (RRMS). METHODS: BRIDGE (RebiSmart to self-inject Rebif serum-free formulation in a multidose cartridge) was a 12-week, multicentre, open-label, single-arm, observational, Phase IV study in which patients self-administered IFN β-1a (titrated to 44 μg), subcutaneously (sc), three times weekly, via electronic autoinjection device. Patients were assessed at baseline and 4-weekly intervals to Week 12 or early termination (ET) for: physical examinations; diary card completion (baseline, Weeks 4, 8 only); neurological examinations (baseline, Week 12/ET only); MS Treatment Concern Questionnaire (MSTCQ; Weeks 4, 8, 12 only); Convenience Questionnaire (Week 12 only); Hospital Anxiety and Depression Scale (HADS); and Paced Auditory Serial Addition Task (PASAT; baseline only). Adherence was defined as administration of ≥ 80% of scheduled injections, recorded by the autoinjection device. RESULTS: Overall, 88.2% (105/119; intent-to-treat population) of patients were adherent; 67.2% (80/119) administered all scheduled injections. Medical reasons accounted for 35.6% (31/87) of missed injections, forgetfulness for 20.6% (18/87). Adherence did not correlate with baseline Expanded Disability Status Scale (P = 0.821) or PASAT (P = 0.952) scores, or pre-study therapy (P = 0.303). No significant changes (baseline-Week 12) in mean HADS depression (P = 0.482) or anxiety (P = 0.156) scores were observed. 'Overall convenience' was the most important reported benefit of the autoinjection device. Device features associated with handling and ease of use were highly rated. Mean MSTCQ scores for 'flu-like' symptoms (P = 0.022) and global side effects (P = 0.002) significantly improved from Week 4-12. Mean MSTCQ scores for pain at injection site and injection pain increased from Week 4-12 (P < 0.001). Adverse events were mild/moderate. No new safety signals were identified. CONCLUSION: Convenience and ease of use of the autoinjection device may improve adherence and, therefore, outcomes, in patients with RRMS receiving sc IFN β-1a. TRIAL REGISTRATION: EU Clinical Trials Register (EU-CTR; http://www.clinicaltrialsregister.eu): 2009-013333-24.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。