Abstract
BACKGROUND: Severe hemophilia is an inherited, lifelong bleeding disorder characterized by spontaneous bleeding, which results in painful joint deformities. Currently two surgical treatments are available to treat haemophilia-related ankle joint destruction: ankle arthrodesis and total ankle replacement. The aim of the present study was to compare these two surgical procedures in haemophiliac subjects. CASE PRESENTATION: Kinematic and dynamic parameters were quantified using a three-dimensional gait-analysis system in two similar clinical cases. In Caucasian case 1, ankle arthrodesis was chosen because of a kinematic ankle flexion defect and lack of dynamic power regeneration. The defect in energy absorption was compensated for by the contralateral side. Total ankle replacement in Caucasian case 2 allowed sparing the ipsilateral knee (maximum 0.27 preoperatively vs. 0.71 W/kg postoperatively) and hip joints powers (maximum 0.43 preoperatively vs. 1.25 W/kg postoperatively) because of the small ankle dorsiflexion motion. CONCLUSIONS: Total ankle replacement is recommended for haemophiliac patients who present with a preserved ankle range of motion.