Efficacy of rFIXFc versus rIX-FP for the Treatment of Patients with Hemophilia B: Matching-Adjusted Indirect Comparison of B-LONG and PROLONG-9FP Trials

rFIXFc 与 rIX-FP 治疗 B 型血友病患者的疗效比较:B-LONG 和 PROLONG-9FP 试验的匹配调整间接比较

阅读:1

Abstract

PURPOSE: In patients with hemophilia B, treatment with extended half-life (EHL) recombinant factor IX allows for longer dosing intervals while providing equal or superior bleeding protection compared with standard half-life products. This enables flexible, individualized treatment schedules, which reduce the burden of prophylaxis and improve patient outcomes. This analysis compared the efficacy of recombinant factor IX Fc fusion protein (rFIXFc) and recombinant factor IX albumin fusion protein (rIX-FP), two EHL therapies approved for prophylaxis and treatment of bleeding in hemophilia B. PATIENTS AND METHODS: Matching-adjusted indirect treatment comparison (MAIC) was used to adjust the between-treatment differences in baseline characteristics. Individual patient data for rFIXFc (B-LONG) were matched to aggregated data for rIX-FP (PROLONG-9FP) followed by statistical comparison for estimated annualized bleeding rate (ABR) using a Poisson regression model with adjustment for over dispersion. Data were analyzed according to treatment regimen prior to study entry: prior prophylaxis (rFIXFc, n=48; rIX-FP, n=40) or prior episodic treatment (n=43 and n=19, respectively). Relative treatment effects are presented as incidence rate ratios (IRR) with 95% confidence intervals (CI). RESULTS: After adjustment for baseline characteristics, estimated ABR observed for rFIXFc and rIX-FP was not significantly different in patients on prior prophylaxis (1.87 versus 1.58; IRR 1.18, 95% CI 0.67-2.10) or prior episodic (2.25 versus 2.22; IRR 1.01 95% CI 0.40-2.57) regimens. CONCLUSION: This MAIC analysis shows that the estimated ABR for rFIXFc-treated patients from B-LONG was similar to that of rIX-FP-treated patients from PROLONG-9FP and, therefore, indicates that the two EHL therapies provide similar efficacy when used as prophylaxis for patients with hemophilia B. Trough levels differ between the two products (1-3% [targeted] versus 20% [observed], respectively), suggesting that trough level is not a surrogate indicator when ABR is used as a criterion for clinical efficacy when comparing these FIX products in hemophilia B.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。