Three-dimensional motion analysis with Synex. Comparative biomechanical test series with a new vertebral body replacement for the thoracolumbar spine

Synex三维运动分析。与新型胸腰椎椎体置换术的对比生物力学测试系列

阅读:1

Abstract

The authors present a new implant for vertebral body replacement in the thoracic and lumbar spine. Synex is a titanium implant designated for reconstruction of the anterior column in injury, post-traumatic kyphosis or tumour of the thoracolumbar spine and must be supplemented by a stabilizing implant. After positioning, the implant is distracted in situ, thus ensuring best contact with adjacent end-plates and three-dimensional (3D) stability, and minimizing the possibility of secondary dislocation or loss of correction. We compared the effectiveness of the Synex implant with that of the "Harms cage" (MOSS) in combination with two alternative stabilizing instrumentations: the USS and Ventrofix. In a 3D spinal loading simulator, we determined the bisegmental (T12-L2) neutral zone (NZ), elastic zone (EZ), and range of motion (ROM) of 12 human cadaveric spines. After corpectomy of L1, we tested the four possible combinations of stabilizing instrumentation and vertebral replacement implant: USS/Synex, USS/MOSS, Ventrofix/Synex, Ventrofix/MOSS. We analysed the differences between each of the instrumentations as well as differences compared to the intact spine. Comparing the two stabilizing implants, a significantly higher stability was achieved with the USS for flexion, extension, and lateral bending, regardless of whether Synex or MOSS was used as vertebral body replacement. No differences were observed for axial rotation. In addition, no implant combination was able to restore the rotational stability of the intact spine. Comparing the vertebral body replacing implants, significantly higher stability was noted with Synex in combination with USS for extension, lateral bending, and axial rotation. No differences between Synex and MOSS were observed in combination with Ventrofix. Posterior fixation was found to offer superior stability compared to anterior fixation. Synex was at least comparable to MOSS for suspensory replacement of the vertebral body in the thoracolumbar spine. The increased biomechanical stability demonstrated for Synex suggests that a more rigid construction would also be achieved in vivo. When using MOSS in combination with posterior stabilization, the induction of intervertebral compression via the posterior fixator is recommended. This surgical step was not necessary with Synex.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。