A Simple Method for Normalization of Aortic Contractility

一种使主动脉收缩力正常化的简便方法

阅读:1

Abstract

Vascular contractile function changes in proliferative vascular diseases, e.g. atherosclerosis, and is documented using isolated blood vessels; yet, many laboratories differ in their approach to quantification. Some use raw values (e.g., mg, mN); others use a "percentage of control agonist" approach; and others normalize by blood vessel characteristic, e.g. length, mass, etc. A lack of uniformity limits direct comparison of contractility outcomes. To address this limitation, we developed a simple 2-step normalization method: (1) measure blood vessel segment length (mm), area (mm2) and calculate volume (mm3); then, (2) normalize isometric contraction (mN) by segment length and volume. Normalized aortic contractions but not raw values were statistically different between normal chow and high-fat diet-fed mice, supporting the practical utility and general applicability of normalization. It is recommended that aortic contractions be normalized to segment length and/or volume to reduce variability, enhance efficiency, and to foster universal comparisons across isometric myography platforms, laboratories, and experimental settings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。