Ion release and surface roughness of silver soldered bands with two different polishing methods: An in-vitro study

两种不同抛光方法对银焊带离子释放和表面粗糙度的影响:一项体外研究

阅读:1

Abstract

OBJECTIVE: To evaluate the surface roughness and ion release of silver-soldered joints by using two polishing methods. METHODS: 174 orthodontic bands with and without silver-soldered joints were evaluated and divided into three groups: two experimental, with different polishing methods (SP1 and SP2), and one control (SS) composed of bands without silver solder. For ionic release, 50 bands of each group were immersed in saline solution and submitted to atomic absorption spectrophotometry to quantify the amount of Fe, Ni, Cr (in all the three groups), Ag, Cu, Cd, and Zn (in the two experimental groups). A rugosimeter was employed to verify the surface roughness. RESULTS: Ni and Cr were released in higher amounts after soldering. Cd, Ag, Zn, and Cu may be released from silver-soldered bands independently of the polishing method employed. Ag was released in higher amounts from the soldered bands that presented higher surface roughness. CONCLUSIONS: Differences exist in relation to the surface roughness of silver-soldered bands when distinct polishing methods are used. Toxic ions may be released from silver soldered joints and higher surface roughness may cause higher ionic release.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。