Right ventricular lead location and outcomes among patients with cardiac resynchronization therapy: A meta-analysis

右心室导线位置与心脏再同步治疗患者预后的关系:一项荟萃分析

阅读:1

Abstract

BACKGROUND: Cardiac resynchronization therapy (CRT) has been demonstrated to improve heart failure (HF) symptoms, reverse LV remodeling, and reduce mortality and HF hospitalization (HFH) in patients with a reduced left ventricular (LV) ejection fraction (LVEF). Prior studies examining outcomes based on right ventricular (RV) lead position among CRT patients have provided mixed results. We performed a systematic review and meta-analysis of randomized controlled trials and prospective observational studies comparing RV apical (RVA) and non-apical (RVNA) lead position in CRT. METHODS: Our meta-analysis was constructed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for systematic reviews and meta-analyses. We searched EMBASE and MEDLINE. Eligible studies reported on at least one of the following outcomes of interest: all-cause mortality, the composite endpoint of death and first HFH hospitalization, change in LVEF, New York Heart Association (NYHA) class improvement, and change in LV end systolic volume (LVESV). We performed meta-analysis summaries using a DerSimonian-Laird random-effects model and conservatively used the Knapp-Hartung approach to adjust the standard errors of the estimated model coefficients. RESULTS: We included nine studies representing a total of 1832 patients. Of those, 1318 (72%) patients had RVA lead placement and 514 (28%) had RVNA lead placement. The mean age of patients was 65.5 ± 4.4 years, and they were predominantly men (69%-97%). There was no statistically significant difference in all-cause mortality by RVA vs. RVNA (OR = 0.77, 95% CI 0.32-1.89; I(2) = 16.7%, p = 0.31), or in the combined endpoint of all-cause mortality and first HFH (OR 0.88, 95% CI 0.62-1.25; I(2) = 0%, p = 0.84). Also, there was no difference between RVA and RVNA for NYHA class improvement (OR = 1.03, 95% CI 0.9-1.17; I(2) = 0%, p = 0.99), change in LVEF (mean difference (MD) = 1.33, 95% CI -1.45 to 4.10; I(2) = 47%; p = 0.093), and change in LVESV (MD = -1.11, 95% CI -3.34 to 1.12; I(2) = 0%; p = 0.92). CONCLUSION: This meta-analysis shows that in CRT pacing, RV lead position does not appear to be associated with clinical outcomes or LV reverse remodeling. Further studies should focus on the relationship of RV lead vis-à-vis LV lead location, and its clinical importance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。