Fracture Resistance of Zirconia Restorations with Four Different Framework Designs

四种不同支架设计的氧化锆修复体的抗折强度

阅读:1

Abstract

Objectives: This study assessed the fracture resistance of zirconia crowns with four framework designs, fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) technology. Materials and Methods: In this experimental study, a maxillary central incisor was prepared and scanned with a CAD/CAM scanner, and 40 frameworks with 4 designs (N=10) were fabricated as follows: simple core, dentine core with a design similar to dentine, 3mm trestle design collar in the lingual aspect with proximal buttresses, and monolithic or full-contour. After porcelain applying and 20h immersion in distilled water (37°C), crowns were cemented on metal dies using zinc phosphate cement. Fracture resistance was measured by a universal testing machine. Data were analyzed with one-way ANOVA (alpha=0.05). Results: Fracture resistance was maximum in the monolithic group, followed by the dentine core, trestle design, and simple core groups, respectively. The mean fracture resistance of the monolithic group was significantly higher than that of the simple core group (P<0.005). Conclusion: Zirconia restorations with frameworks that provided higher and more support for porcelain, showed increased fracture resistance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。