Measurement by a Novel LC-MS/MS Methodology Reveals Similar Serum Concentrations of Vitamin D-Binding Protein in Blacks and Whites

采用新型 LC-MS/MS 方法测量发现黑人和白人血清中的维生素 D 结合蛋白浓度相似

阅读:4
作者:Clark M Henderson, Pamela L Lutsey, Jeffrey R Misialek, Thomas J Laha, Elizabeth Selvin, John H Eckfeldt, Andrew N Hoofnagle

Background

Vitamin D deficiency is associated with poor bone health and other adverse health outcomes; however, the associations are greatly attenuated in black vs white individuals. One possible explanation for this attenuation is different concentrations of bioavailable vitamin D metabolites in plasma, which are estimated with equations that include the total concentration of vitamin D binding globulin (VDBG) and haplotype-specific dissociation constants.

Conclusions

Validated mass spectrometric methods for the quantification of proteins in human samples can provide additional information beyond immunoassay. Counter to prior observations by immunoassay, VDBG concentrations did not vary by race.

Methods

We developed a method to quantify VDBG with LC-MS/MS that could also identify the haplotypes/isoforms of VDBG present. We validated the method according to recent recommendations for publications of biomarker studies. We determined serum VDBG concentrations in samples from the Atherosclerosis Risk in Communities cohort and compared the

Results

With 10 μL of serum or plasma, the lower limit of quantification for the assay (<20% CV) was 71 μg/mL. The assay was linear from 62 to 434 μg/mL, with total imprecision of 7.3-9.0% CV at approximately 250 μg/mL. Significant hemolysis interfered with quantification. The identification of isoforms was 97% concordant with genotyping (κ coefficient). Method comparison with immunoassay revealed significant isoform-specific effects in the immunoassay. Mean concentrations (SD) of VDBG by mass spectrometry were similar in whites and blacks [262 (25) vs 266 (35) μg/mL, respectively; P = 0.43]. Conclusions: Validated mass spectrometric methods for the quantification of proteins in human samples can provide additional information beyond immunoassay. Counter to prior observations by immunoassay, VDBG concentrations did not vary by race.