Selective internal radiation therapy of hepatic tumors: Morphologic and functional imaging for voxel-based computer-aided dosimetry

肝肿瘤的选择性内放射治疗:基于体素的计算机辅助剂量测定的形态学和功能成像

阅读:5
作者:Andrea Skanjeti, Nicolas Magand, Didier Defez, Jeremie Tordo, Agnes Rode, Anne Frederique Manichon, François Hallouard, Caroline Clave-Darcissac, Anthony Dhomps, Danyelle M Townsend, Domenico Rubello, Francesco Giammarile

Conclusion

Post-treatment imaging remains paramount to estimate the irradiation dosimetry, due to an imperfect overlap. The perfused volume could be estimated from functional imaging, given its impact on dosimetry. Finally, survival seems related to tumoral overlap and dosimetry.

Material and methods

A total of 19 patients underwent 21 SIRT after baseline angiography and 99mTc-MAA SPECT/CT, followed by 90Y PET/CT. Overlap between 99mTc-MAA and 90Y-microspheres was quantified with different thresholds isocontours. The perfused volume and tumor absorbed dose were estimated using Simplicit90Y™ based on SPECT/CT and PET/CT, then compared with the supplier suggested method. These data were related to overall survival to evaluate their prognostic impact.

Methods

A total of 19 patients underwent 21 SIRT after baseline angiography and 99mTc-MAA SPECT/CT, followed by 90Y PET/CT. Overlap between 99mTc-MAA and 90Y-microspheres was quantified with different thresholds isocontours. The perfused volume and tumor absorbed dose were estimated using Simplicit90Y™ based on SPECT/CT and PET/CT, then compared with the supplier suggested method. These data were related to overall survival to evaluate their prognostic impact.

Results

The overlap between PET/CT and SPECT/CT was dependent on thresholds, decreasing with an increasing threshold. The overlap between the 99mTc-MAA and 90Y-microspheres biodistributions versus the tumor distribution on morphological imaging was suboptimal, in particular for small tumor volume. The tumor absorbed dose estimated after 90Y PET/CT was not different from tumor absorbed dose estimated after SPECT/CT. The Perfused lobe absorbed dose was significantly lower while the volume of the perfused lobe was significantly higher when estimated by Simplicit90Y™ compared to the supplier suggested conventional approach. A statistical parameter based on overlap between tumor and 90Y-microspheres distribution as well as tumoral dosimetry was significantly related to the overall survival.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。