Direct measurement of internal temperatures of commercially-available 18650 lithium-ion batteries

直接测量市售18650锂离子电池的内部温度

阅读:1

Abstract

Direct access to internal temperature readings in lithium-ion batteries provides the opportunity to infer physical information to study the effects of increased heating, degradation, and thermal runaway. In this context, a method to insert temperature sensors into commercial 18650 cells to determine the short- and long-term effects through characterization testing is developed. Results show that sensor insertion only causes a decrease in capacity of 0.5-2.3%, and an increase in DC resistance of approximately 15 mΩ. The temperatures of the modified cells are approximately 0.5 °C higher than the control cells, the difference between the internal and external temperature readings of the modified cells is approximately 0.4 °C, and the modified cells exhibit the same temperature behavior and trend during cycling as the control cells. The cells are able to operate and collect data for 100-150 cycles before their capacities fade and resistances increase beyond what is observed in the control cells. The results of the testing show that cells modified with internal temperature sensors provide useful internal temperature data for cells that have experienced little or no cyclic aging.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。