The modern structurator: increased performance for calculating the structure function

现代结构化器:结构函数计算性能提升

阅读:1

Abstract

The autocorrelation function is a statistical tool that is often combined with dynamic light scattering (DLS) techniques to investigate the dynamical behavior of the scattered light fluctuations in order to measure, for example, the diffusive behavior of transparent particles dispersed in a fluid. An alternative approach to the autocorrelation function for the analysis of DLS data has been proposed decades ago and consists of calculating the autocorrelation function starting from difference of the signal at different times by using the so-called structure function. The structure function approach has been proven to be more robust than the autocorrelation function method in terms of noise and drift rejection. Therefore, the structure function analysis has gained visibility, in particular in combination with imaging techniques such as dynamic shadowgraphy and differential dynamic microscopy. Here, we show how the calculation of the structure function over thousands of images, typical of such techniques, can be accelerated, with the aim of achieving real-time analysis. The acceleration is realized by taking advantage of the Wiener-Khinchin theorem, i.e., by calculating the difference of images through Fourier transform in time. The new algorithm was tested both on CPU and GPU hardware, showing that the acceleration is particularly large in the case of CPU.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。