BACKGROUND AND PURPOSE: Ureteroscope breakage is commonly related to laser fiber damage. Often, the damage is mechanical and not energy related. As such, we evaluated a novel laser fiber and sheath system in preventing mechanical ureteroscope damage during fiber insertion. MATERIALS AND METHODS: We assessed 200-μm/272/3-μm laser fibers with the laser sheath in a flexible ureteroscope. Diminishment of active deflection and irrigation flow rates were compared with a standard laser fiber alone. Eight nonassembled working channel components were tested in a 0-degree/90-degree/210-degree deflection model. After insertion cycles, external and endolumenal damage to the working channel were classified. We also tested the sheath system in a 0-degree/90-degree/210-degree deflection model for fiber failure and laser damage. RESULTS: In all test trials with the sheath and for standard laser fibers in the 0-degree model, there were no channel perforations or damage. With standard laser fibers, in the 210-degree model, superficial scratches and demarcated abrasions were visible after 10 and 60 to 70 insertions for the 273-μm laser fiber and after 30 insertions (superficial scratches) for the 200-μm laser fiber. In the 90-degree model, superficial scratches occurred after 20 insertions for the 273-μm fibers and after 40 insertions for the 200-μm laser fibers. No demarcated abrasions were seen after 100 insertions. In the 210-degree model, there was one perforation with the 272-μm fiber, but none with 200-μm fiber. There were no fiber failures with sheath use; however, the sheath did not prevent laser energy damage. The laser sheath resulted in a 4.7-degree/3.8-degree (1.2%/1.5%) diminishment in deflection (up/down) for the 200 μm and a 3.5-degree/4.3-degree (1.8%/1.5%) diminishment for 272-μm laser fiber compared with standard 200/272-μm laser fiber. Irrigation flow was diminished with the sheath on both the 200-μm and 272-μm laser fiber by 28.7% and 32.6%, respectively. CONCLUSION: The Scope Guardian Sheath prevented mechanical working channel damage with minimal diminishment of deflection and irrigation flow.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。