Precurved non-tunnelled catheters for haemodialysis are comparable in terms of infections and malfunction as compared to tunnelled catheters: A retrospective cohort study

一项回顾性队列研究表明,用于血液透析的预弯非隧道式导管在感染和功能障碍方面与隧道式导管相当。

阅读:1

Abstract

BACKGROUND: The main limitations of central venous catheters for haemodialysis access are infections and catheter malfunction. Our objective was to assess whether precurved non-tunnelled central venous catheters are comparable to tunnelled central venous catheters in terms of infection and catheter malfunction and to assess whether precurved non-tunnelled catheters are superior to straight catheters. MATERIALS AND METHODS: In this retrospective, observational cohort study, adult patients in whom a central venous catheter for haemodialysis was inserted between 2012 and 2016 were included. The primary endpoint was a combined endpoint consisting of the first occurrence of either an infection or catheter malfunction. The secondary endpoint was a combined endpoint of the removal of the central venous catheter due to either an infection or a catheter malfunction. Using multivariable analysis, cause-specific hazard ratios for endpoints were calculated for tunnelled catheter versus precurved non-tunnelled catheter, tunnelled catheter versus non-tunnelled catheter, and precurved versus straight non-tunnelled catheter. RESULTS: A total of 1603 patients were included. No difference in reaching the primary endpoint was seen between tunnelled catheters, compared to precurved non-tunnelled catheters (hazard ratio, 0.91; 95% confidence interval, 0.70-1.19, p = 0.48). Tunnelled catheters were removed less often, compared to precurved non-tunnelled catheters (hazard ratio, 0.65; 95% confidence interval, 0.46-0.93; p = 0.02). A trend for less infections and catheter malfunctions was seen in precurved jugular non-tunnelled catheters compared to straight non-tunnelled catheters (hazard ratio, 0.60; 95% confidence interval, 0.24-1.50; p = 0.28) and were removed less often (hazard ratio, 0.41; 95% confidence interval, 0.18-0.93; p = 0.03). CONCLUSION: Tunnelled central venous catheters and precurved non-tunnelled central venous catheters showed no difference in reaching the combined endpoint of catheter-related infections and catheter malfunction. Tunnelled catheters get removed less often because of infection/malfunction than precurved non-tunnelled catheters.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。