Multiscale Simulation of Adsorption Based Microcantilever Biosensors for Radiation Exposure Effects

基于吸附的微悬臂梁生物传感器在辐射暴露效应方面的多尺度模拟

阅读:2

Abstract

BACKGROUND: This article is focused on biological measurements based on molecular interactions. The specific biomarker implemented for radiation biosensor is FLT3, which bears changes in the body regarding radiation exposure. Experimental results of sensing vancomycin verify the overall results of two steps of numerical methods for different scales. OBJECTIVES: The aim is to provide adequate modeling procedures to predict sensory data. Multiscale modeling is implemented to simulate molecular interaction and its consequent micro mechanical effects. The method is implemented to calculate surface traction of microcantilever biosensor. MATERIALS AND METHODS: The method consists of molecular dynamics simulation of adsorption process by implementing classical mechanics theory to calculate the final response of the sensor as tip deflection. The sequential information transaction is assumed between the physical parameters of two governing scales. The numerical method consists of the location of particles providing for a nano-metric periodic boundary conditioned functionalized surface implemented, and the numerical thermodynamic formula is, in turn, use energy parameters to acquire macro-mechanical deflection of a specific microcantilever. Also, novel sensitivity analysis of the results as the adsorption process moves toward more saturated substrate provided. RESULTS: Verification of the simulation method for Vancomycin sensing results enjoys less than 20 percent of deviation regarding the experimental data. The standard deviation of 0.054 in the final expected response of the sensor is calculated as the accuracy of the radiation biosensor based on FLT3. CONCLUSIONS: The method is still to reach a correlation between the concentration of target molecules in solution and the number of adsorbed molecules per area of the sensor. A scaled correlation between sensor's response and the amount of biomarker is found using tip deflection of a sample designed microcantilever. Around one micrometer deflection that can be read out using various conventional methods was observed at saturation of adsorption surface. The analyses provide adequate data to design a sensor capable of measuring the effect of cosmic radiation to the human body.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。