Impact of Laser Power and Firing Angle on Coagulation Efficiency in Laser Treatment for Twin-Twin Transfusion Syndrome: An ex vivo Placenta Study

激光功率和发射角度对双胎输血综合征激光治疗中凝血效率的影响:一项离体胎盘研究

阅读:2

Abstract

OBJECTIVE: To assess the impact of laser power and firing angle on coagulation efficiency for closing placental anastomoses in the treatment of twin-twin transfusion syndrome. METHODS: We used an ex vivo blood-perfused human placenta model to compare time to complete coagulation using 30 vs. 50 W of neodymium-doped yttrium aluminum garnet laser power and using a firing angle of 90° vs. 45°. Placentas were perfused with pig blood at 5 mL/min. Differences were analyzed using independent-samples t test, Mann-Whitney U test, or χ2 test as appropriate. RESULTS: Coagulation took less time and energy using 50 W (n = 53) compared to 30 W (n = 52), 11 vs. 22 s (p < 0.001), and 557 vs. 659 J (p = 0.007). Perpendicular coagulation (n = 53) took less time and energy compared to a 45° angle (n = 21), 11 vs. 17 s (p = 0.004), and 557 vs. 871 J (p = 0.004). Bleeding complicated 2 (3%) measurements in the 50-W group, 5 (10%) in the 30-W group, and 3 (14%) in the 45° group. DISCUSSION: In a highly controlled model, a 50-W laser power setting was more energy efficient than 30 W in coagulating a placental vein. A more perpendicular laser firing angle resulted in more efficient coagulation. Furthermore, bleeding due to vessel wall disruption occurred more often with lower power and a more tangential approach.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。