Large-Displacement Vertical Electrostatic Microactuator Dynamics using Duty-Cycled Softening/Stiffening Parametric Resonance

利用占空比软化/硬化参数共振实现大位移垂直静电微致动器动力学

阅读:1

Abstract

Electrostatic microactuators with large vertical scanning range (several hundred microns) at high frequency (hundreds to thousands of hertz) and chips sizes compatible with endoscopic microscopy have recently been demonstrated based on parametric resonance. This paper examines the use and modeling of mixed softening/hardening dynamics to help produce large ranges of motion in this class of mirrors. Origin of spring stiffening behavior in actuator design is described, followed by non-dimensional analysis of actuator motion trends. Experimental results are presented for a sample actuator design with up to 480 μm displacement at 1225 Hz and 60 V. Comparison to predicted trends and comments on benefits and limitations of modeling are provided.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。