Validity of the 6-Minute Walk Test and YMCA Submaximal Cycle Test During Midpregnancy

妊娠中期6分钟步行试验和YMCA次极量自行车试验的有效性

阅读:1

Abstract

Tinius, RA, Blankenship, M, Maples, JM, Pitts, BC, Furgal, K, Norris, ES, Hoover, DL, Olenick, A, Lambert, J, and Cade, WT. Validity of the 6-minute walk test and Young Men's Christian Association (YMCA) submaximal cycle test during midpregnancy. J Strength Cond Res 35(11): 3236-3242, 2021-Submaximal exercise testing can be a feasible alternative to maximal testing within special populations to safely predict fitness levels; however, submaximal exercise testing has not been well-validated for use during pregnancy. The purpose of this study was to determine the concurrent validity of the 6-minute walk test (6MWT) and the YMCA submaximal cycle test (YMCAT) to predict V̇o2max in physically active women during midpregnancy. Thirty-seven (n = 37) pregnant women (22.1 ± 1.4 weeks' gestation) and 10 (n = 10) nonpregnant women participated in the study. Subjects completed a graded maximal treadmill test at 1 visit to measure maximal oxygen consumption (V̇o2max), and then subjects completed the 6MWT and YMCAT in randomized order during a separate visit. The predicted V̇o2max from each submaximal test were compared with the measured V̇o2max from the treadmill test to assess the validity of these tests during pregnancy. Among pregnant women, predicted V̇o2max from the YMCAT was not correlated to the measured V̇o2max (r = 0.14, p = 0.42), and the predicted V̇o2max from the 6MWT was only moderately correlated (r = 0.40, p = 0.016) to the measured V̇o2max. Among nonpregnant women, the predicted V̇o2max values from both the YMCAT and the 6MWT had strong correlations with the measured V̇o2max values (YMCAT: r = 0.71, p = 0.02; 6MWT: r = 0.80, p = 0.006). Neither test demonstrated concurrent validity among the pregnant sample. The main finding is that the YMCAT is not a valid method to estimate V̇o2max during midpregnancy (likely due to physiological changes in heart rate [HR] during pregnancy). The 6MWT has potential to be used clinically for estimating fitness as actual and predicted values did positively correlate, and it is not dependent on HR responses to exercise. However, if a precise measure of fitness is needed, then neither test appears to have strong validity for use during midpregnancy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。