Cut-Off Value of Medial Meniscal Extrusion for Knee Pain

内侧半月板挤出程度与膝关节疼痛的临界值

阅读:1

Abstract

Purpose. Medial meniscal extrusion (MME) has attracted attention as an index of knee pain in conjunction with clinical symptoms that could be more useful than the diagnosis of knee osteoarthritis on X-ray. However, the size of MME that would cause knee pain has not been clarified. The aim of the present study was to investigate the cut-off value of MME for knee pain. Methods. A total of 318 knees were evaluated. The presence of current or past knee pain was confirmed by interview. Next, MME was measured using vertical sonographic images of the medial joint spaces during weightbearing. Results. Overall, 71 knees were painful (P-group), and 247 knees were not (N-group). MME was 5.9 ± 1.8 mm in the P-group and 2.9 ± 1.5 mm in the N-group (P < 0.0001). Analysis of the receiver operating characteristic curve showed that the cut-off value of MME for knee pain was 4.3 mm, with sensitivity of 0.8451 and specificity of 0.8502. In addition, 64% of knees without pain cases at the time of examination whose MME exceeded this cut-off value had past knee pain. Conclusions. The sensitivity and specificity of MME for knee pain were very high with a cut-off value of 4.3 mm.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。