In vitro assessment of an engineered tBID-based safety switch system in human T lymphocytes

对人类 T 淋巴细胞中基于 tBID 的工程安全开关系统的体外评估

阅读:8
作者:Jiamiao Lu #, Patrick Collins #, Ki Jeong Lee, Chi-Ming Li, Songli Wang

Background

Cell therapy as a promising therapeutic modality to treat cancer has been intensively studied for decades. However, the clinical trials have indicated that patients under T cell therapy may develop severe cytokine release syndrome resulting in hospitalization or even death. Furthermore, genetic modifications to promote proliferation and persistence of T cells could result in high numbers of long-lived engineered cells in patients after treatment.

Conclusions

We demonstrated that our engineered tBID-based safety switch was able to eliminate up to ~90% of transduced human primary T cells within 72 h after activation, providing an alternative switch system to manage safety concerns for cell therapy.

Methods

We incorporated the pro-apoptotic truncated BH3 interacting-domain death agonist (tBID) with the mutant ecDHFR destabilizing domain to form a novel recombinant protein as the major component of an engineered tBID-based safety switch system, which would be unstable and quickly degraded in the absence of trimethoprim (TMP) but, upon TMP treatment, should become stabilized and allow tBID to induce cell death experimentally.

Results

The novel tBID-based safety switch could be regulated through a small molecule inducer, TMP, to control undesired toxicity or ablate the engineered cells as needed. We systematically compared and assessed several tBID-based safety switch constructs with the clinically validated safety switches, including human herpes simplex virus thymidine kinase (HSV-TK) and inducible Caspase 9 (iCasp9). With optimization, we were able to achieve significant killing potency in vitro in Jurkat or human primary T cells. Conclusions: We demonstrated that our engineered tBID-based safety switch was able to eliminate up to ~90% of transduced human primary T cells within 72 h after activation, providing an alternative switch system to manage safety concerns for cell therapy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。