Lipoprotein(a)-cholesterol levels estimated by vertical auto profile correlate poorly with Lp(a) mass in hyperlipidemic subjects: Implications for clinical practice interpretation of Lp(a)-mediated risk

在血脂异常患者中,通过垂直自动分析法估算的脂蛋白(a)胆固醇水平与Lp(a)质量的相关性较差:对临床实践中Lp(a)介导风险解读的启示

阅读:1

Abstract

BACKGROUND: Lipoprotein(a) [Lp(a)] is generally measured as total mass of the entire particle or as apolipoprotein(a) particle number. OBJECTIVE: The cholesterol content of Lp(a) [Lp(a)-C)] can be estimated by the vertical auto profile (VAP) method. We assessed whether this is an accurate surrogate measurement of Lp(a) mass. METHODS: VAP-Lp(a)-C and VAP-high density lipoprotein cholesterol (HDL-C) estimated by the VAP technique, Lp(a) mass, oxidized phospholipids on apolipoprotein B-100 (OxPL-apoB) that primarily reflect OxPL on Lp(a), and HDL-C measured by enzymatic methods were measured in 552 hypercholesterolemic patients at baseline and 24 weeks after therapy with niacin monotherapy (N = 118), ezetimibe/simvastatin monotherapy (n = 155), or ezetimibe/simvastatin (10/20 mg) + niacin (to 2 g) (N = 279) in a randomized, double-blind trial. RESULTS: VAP-Lp(a)-C correlated only modestly with Lp(a) mass at baseline (r = 0.56, P < .001) and 24 weeks (r = 0.56, P < .001), explaining only 31% of the association. VAP-Lp(a)-C correlated with HDL-C at baseline (r = 0.34, P < .001) and 24 weeks (r = 0.30, P < .001) and with VAP-HDL-C at baseline (r = 39, P < .001) and 24 weeks (r = 0.33, P < .001). In contrast, Lp(a) mass did not correlate with HDL-C at baseline (r = 0.06, P = .12) and 24 weeks (r = -0.01 P = .91). Lp(a) mass correlated strongly with oxidized phospholipids on apolipoprotein B-100 at baseline (r = 0.81, P < .001) and 24 weeks (r = 0.79, P < .001). VAP-Lp(a)-C levels increased linearly with HDL-C and VAP-HDL-C quartiles (P < .001 for both) but Lp(a) mass did not. Quantitating the percent of cholesterol present on Lp(a) by dividing VAP-Lp(a)-C by Lp(a) mass revealed that 25% of patients had a percentage >100, which is not possible. CONCLUSIONS: VAP-Lp(a)-C is a poor estimate for Lp(a) mass and likely reflects the content of HDL-C in the overlapping density spectrum of Lp(a) and HDL. These data suggest that patients with prior VAP-Lp(a)-C measurements may have misclassification of Lp(a)-related risk.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。