System accuracy evaluation of the new blood glucose monitoring meter "GLUCOCARD S onyx" beyond ISO 15197:2013/EN ISO 15197:2015 requirements and with new patient safety features

对新型血糖监测仪“GLUCOCARD Sonyx”的系统精度进行评估,该评估超越了 ISO 15197:2013/EN ISO 15197:2015 的要求,并具备新的患者安全功能。

阅读:1

Abstract

INTRODUCTION: Blood glucose monitoring meters (BGM) have not become redundant yet. The accuracy and precision of "GLUCOCARD S onyx," a new BGM with Bluetooth function, has been evaluated and proven to exceed the actual ISO 15197:2013/EN ISO 15197:2015 guidelines besides offering features for better patient safety and telemedicine. METHODS: 100 finger-prick whole blood samples from subjects with diabetes and 32 without diabetes were collected and measured with GLUCOCARD S onyx. Plasma blood glucose levels were measured using YSI2300 STAT PLUS as reference analyzer for comparison. The evaluation followed ISO 15197:2013, section 6.3 accuracy criteria. Furthermore, the MARD factor was calculated for the overall clinical important range (with n=132 samples). RESULTS: The performance of GLUCOCARD S onyx was evaluated according to ISO 15197:2013, revealing that 99.7% (598/600) of the results fell within ±15% or ±0.8 mmol/L (± 15 mg/dL) of difference over the total clinically relevant glucose range compared to the YSI2300 STAT PLUS. 100% (600/600) of the measurement results over the total range fell within Clark Error Grid Zone A. An overall mean absolute relative difference (MARD) factor of 4.15% was obtained; 5.05% for glucose <5.6 mmol/L (<100 mg/dL), and 3.65% for glucose ≥5.6 mmol/L (≥100 mg/dL). DISCUSSION: GLUCOCARD S onyx shows clinically satisfactory accuracy and reliability, even exceeding the ISO 15197:2013 criteria, for hypoglycemic cases with glucose critically low as <3.9 mmol/L (<70 mg/dL) and hyperglycemic cases with glucose ≥10.0 mmol/L (≥180 mg/dL). Healthcare organizations as well as manufacturers are aiming to offer new BGM systems that go beyond the ISO criteria and offer systems that can be consulted instead or besides CGM (Continuous Glucose Monitoring) in case of e.g. severe hypo- and/or hyperglycemic episodes. A MARD factor of 4.15% revealed an excellent system accuracy over the total clinically relevant glucose range. With additional user-friendly features, this BGM can be seen as a useful tool for efficient diabetes therapy, especially in the event of severe blood glucose fluctuations.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。