Determination of sperm concentration using flow cytometry with simultaneous analysis of sperm plasma membrane integrity in zebrafish Danio rerio

使用流式细胞术测定斑马鱼 Danio rerio 的精子浓度并同时分析精子质膜的完整性

阅读:5
作者:Huiping Yang, Jonathan Daly, Terrence R Tiersch

Abstract

Control of sperm concentration is required to ensure consistent and reproducible results for cryopreservation and in vitro fertilization protocols. Determination of sperm concentration is traditionally performed with a counting chamber (e.g., hemocytometer), or more recently with a spectrophotometer. For small-sized biomedical model fishes, the availability of sperm sample is limited to microliters, so it is desirable to develop fast and accurate approaches for concentration determination that also minimize sample use. In this study, a new approach was developed for sperm concentration determination using a flow cytometer (Accuri C6, BD Biosciences, San Jose, CA) with simultaneous measurement of sperm membrane integrity after fluorescent staining with SYBR(®) -14 and propidium iodide (PI) in sperm from Zebrafish Danio rerio. The goal was to develop a protocol for simultaneous determination of sperm quality and quantity by flow cytometry. The objectives were to (1) determine the effects of sample volume (250 and 500 µl) and analysis volume (10 and 50 µl) on the accuracy of particle counting using standard volumetric validation beads; (2) identify the effective range of sperm concentrations that flow cytometry can measure; (3) test the precision and reproducibility of the sperm concentration measurements; and (4) verify the flow cytometry approach by comparison with measurement with a hemocytometer and a microspectrophotometer. Sample volumes of 250 and 500 µl and analysis volumes of 10 and 50 µl did not affect bead count with the factory-set flow rates of "medium" or "fast," and the precision and accuracy was retained across a concentration range of 1 × 10(3) -1 × 10(7) cells/ml. The approach developed in this study was comparable to traditional methodologies such as hemocytometer or microspectrophotometer. This study provides an efficient, accurate, and rapid method for determination of sperm concentration using flow cytometry while providing simultaneous assessment of sperm membrane integrity. Such approaches can reduce the time needed for quantity assessment and maximize the use of valuable sperm samples. © 2015 International Society for Advancement of Cytometry.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。