An Intraoperative Method to Minimize Leg Length Discrepancy in Anterior Minimally Invasive Total Hip Arthroplasty-A Prospective Study

一种术中减少前路微创全髋关节置换术中腿长差异的方法——一项前瞻性研究

阅读:1

Abstract

While several intraoperative devices have been described in the literature for assessing leg length discrepancy (LLD), none have been utilized during total hip arthroplasty (THA) performed via the Anterior Minimally Invasive Surgery (AMIS) approach. The aim of this prospective study was to evaluate the efficacy and accuracy of a compass device in assessing leg length during THA performed using the AMIS technique. A prospective study was conducted involving 35 patients who consecutively underwent unilateral primary THA using the AMIS technique at our department from September 2017 to December 2018. LLD was measured by comparing preoperative and postoperative anteroposterior radiographs of the pelvis, independently assessed by two observers. The mean preoperative LLD was 3.6 (SD 3.9, range, 0.2-19.3) mm. The mean postoperative LLD was 2.5 (SD 3.0, range, 0-12.2) mm. A postoperative LLD of less than 5 mm was observed in 88.2% of cases, with 94.1% having values less than 10 mm. In conclusion, the compass device emerged as a valuable tool for ensuring precise limb length control in THA with the AMIS approach, offering both efficiency and cost-effectiveness in clinical practice.