Optimal Nozzle Position and Patient's Posture to Enhance Drug Delivery into the Peritoneum during Rotational Intraperitoneal Pressurized Aerosol Chemotherapy in a Swine Model

在猪模型中,通过旋转腹腔内加压气溶胶化疗,优化喷嘴位置和患者体位以增强药物向腹膜的输送。

阅读:2

Abstract

Even though rotational intraperitoneal pressurized aerosol chemotherapy (RIPAC) has been developed to improve the distribution and penetration depth of anti-cancer agents by pressurized intraperitoneal aerosol chemotherapy (PIPAC), the optimal nozzle position and patient's posture have not been investigated. Thus, we used nine pigs weighing 50-60 kg, and sprayed 150 mL of 1% methylene blue as an aerosol through the nozzle, DreamPen(®) (Dreampac Corp., Wonju, Republic of Korea), with a flow rate of 0.6 ml/min under a pressure of 140 to 150 psi for RIPAC in six and three pigs with supine and Trendelenburg positions, respectively. When we evaluated its distribution and penetration depth, even distribution among 13 regions of the abdomen was observed in three pigs with Trendelenburg position regardless of the depth of the nozzle. Regarding penetration depth, the numbers of regions with maximal penetration depth were high in the 2 cm depth of the nozzle with supine position (n = 5) and the 4 cm depth with Trendelenburg position (n = 3). Conclusively, even distribution and maximal penetration of anti-cancer agents can be expected during RIPAC in the medium depth (4 cm) between the nozzle inlet and the visceral peritoneum located on the opposite side of it and the Trendelenburg position.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。