Comparative outcomes of Kirschner wire and lag screw fixation in pediatric medial malleolar fractures

儿童内踝骨折中克氏针固定与拉力螺钉固定的疗效比较

阅读:1

Abstract

BACKGROUND: Salter-Harris type III and IV medial malleolar fractures (McFarland fractures) are uncommon but clinically significant injuries in skeletally immature patients, with a substantial risk of premature physeal closure (PPC) and subsequent growth disturbance. Various fixation methods, including Kirschner wires (K-wires) and cannulated screws, are used in clinical practice; however, comparative data on their outcomes in pediatric medial malleolar fractures are limited. METHODS: This retrospective study included 60 patients (38 males, 22 females; mean age 11.57 ± 1.78 years) with Salter-Harris type III or IV medial malleolar fractures treated surgically between 2013 and 2023. Patients were categorized according to the fixation method as Kirschner wire fixation (KWF; n = 26) or lag screw fixation (LSF; n = 34). Radiological outcomes included PPC, residual displacement, and lateral distal tibial angle (LDTA). Clinical outcomes at mid-term follow-up (mean 85.37 ± 37.25 months) comprised ankle range of motion (ROM), pain on the Visual Analogue Scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Score, Foot and Ankle Outcome Score (FAOS), and complications. RESULTS: Baseline characteristics were comparable between groups. Open reduction was performed more frequently in the KWF group (80.8% vs. 55.9%; p = 0.043). PPC occurred in 6 patients (23.1%) in the KWF group and 2 patients (5.9%) in the LSF group, representing a non-significant trend toward a higher PPC rate in the KWF group (p = 0.067). Initial LDTA was similar between groups, whereas final LDTA was higher in the KWF group (93.08 ± 6.60° vs. 90.76 ± 5.05°; p = 0.035) and ΔLDTA was greater in the KWF group (3.65 ± 6.29° vs. 1.62 ± 4.95°; p = 0.027). Clinical outcomes (AOFAS, FAOS, VAS, ROM) did not differ significantly between groups. Implant irritation was more frequent after screw fixation, often leading to elective implant removal. CONCLUSION: Both K-wire and lag screw fixation achieved reliable union and excellent mid-term clinical outcomes in pediatric medial malleolar physeal fractures. Screw fixation was associated with significantly more favorable radiographic alignment (lower final LDTA and smaller ΔLDTA) and a numerically lower PPC rate that did not reach statistical significance. Despite these radiographic differences, functional outcomes were similarly excellent, supporting both techniques as viable options when anatomic reduction is achieved. LEVEL OF EVIDENCE: Level III, retrospective comparative study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。