A novel external fixation for treating tibial fractures: a finite element and biomechanical study

一种治疗胫骨骨折的新型外固定方法:有限元和生物力学研究

阅读:1

Abstract

OBJECTIVE: Design a new type of external fixation device that is small in size, high in strength, and capable of achieving the mechanical requirements for fracture healing. Verify the rationality and effectiveness of the device in treating tibial fractures through finite element analysis and biomechanical comparative tests. METHODS: Finite element simulation was performed on the new external fixation device to treat fractures, to verify whether the mechanical properties of the device meet the requirements of fracture healing. A fracture gap model was created using Sawbones to simulate midshaft tibial comminuted fractures. The experiment was divided into four groups, testing the mechanical characteristics of the new external fixation (NEF), locking compression plate (LCP), the unilateral external fixation (UEF), and the externalized locking compression plate (E-LCP). The axial compression, torsion, fatigue and ultimate load tests were performed separately. Data were collected and statistical analysis was performed to verify whether there were statistical differences between the four groups. RESULTS: The finite element analysis of NEF demonstrated that the fracture end was displaced by 0.512 mm under 700 N loading, and the maximum stress value of the device was 189 MPa, which met the mechanical requirements. Axial compression tests showed that LCP (2108.596 N/mm) had the highest stiffness, and NEF (519.489 N/mm) had higher stiffness than both UEF (327.153 N/mm) and E-LCP (316.763 N/mm) (p < 0.05), but no significant difference between UEF and E-LCP (p = 0.313). There was a significant difference in mean torsional stiffness among UEF (1.412 N·m/deg), NEF (1.398 N·m/deg), LCP (1.128 N·m/deg), and E-LCP (0.838 N·m/deg). No structural failures occurred during fatigue testing spanning 108,000 cycles. In ultimate load tests, NEF withstood the highest load, followed sequentially by LCP, UEF, and E-LCP. Significant differences were found between the groups (p < 0.05), with frame bending and secondary bone fractures noted in post-test evaluations. CONCLUSIONS: The NEF for tibial fractures is well-designed to meet the fracture healing requirements. It has certain advantages in comparison with other fixation methods and can be used as a new method for the treatment of tibial fractures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。