Image-based robotic (ROSA(®) knee system) total knee arthroplasty with inverse kinematic alignment compared to conventional total knee arthroplasty : Study protocol and the inverse kinematic alignment in 8-steps using the ROSA(®) Knee system for knee balancing technique explained

基于影像的机器人辅助(ROSA®膝关节系统)全膝关节置换术联合反向运动学对位与传统全膝关节置换术的比较:研究方案及使用ROSA®膝关节系统进行膝关节平衡技术的8步反向运动学对位详解

阅读:1

Abstract

INTRODUCTION: In 2020, 368 million people globally were affected by knee osteoarthritis, and prevalence is projected to increase with 74% by 2050. Relatively high rates of dissatisfactory results after total knee arthroplasty (TKA), as reported by approximately 20% of patients, may be caused by sub-optimal knee alignment and balancing. While mechanical alignment has traditionally been the goal, patient-specific alignment strategies are gaining interest. Robotic assistance could potentially facilitate implementation of these alignment strategies through data-based surgical planning, accurate execution of the surgical plan and validation. The clinical value of surgical assistance in diverging from mechanical alignment remains to be investigated. In the present study, robotic-assisted TKA will be performed to pursue inverse kinematic alignment (iKA) within predefined boundaries, focusing on restoring native tibia joint line. METHODS: This randomized controlled trial evaluates clinical effectiveness of robotic-assisted TKA (ROSA(®) Knee System, Zimmer Biomet, Montreal, Quebec, Canada) aiming for iKA compared to conventional TKA aiming for mechanical alignment. A total of 150 participants will be randomized (1:1) to either treatment to provide an 80% power for a 4.8-point clinically important difference in the primary outcome measure, the Oxford Knee Score (OKS) 12 months after surgery. Allocation was achieved using computer-based randomization. Outcomes will be analyzed using linear mixed models with time and group as main factors and interaction-term. Secondary outcomes include clinical metrics (leg alignment, implant and patient survival), surgical parameters (adverse events, surgery duration, blood loss, hospital stay length, medication use), patient-reported outcomes (symptoms, quality of life, pain), mobility and physical activity measurements, metabolic syndrome, cost-efficacy, and gait and continuous glucose monitoring. ETHICS AND DISSEMINATION: This study has been approved by the Medical Ethical Committee Zuyd and Zuyderland Medical Centre (NL79161.096.21/METCZ20220006), September 2022. TRIAL REGISTRATION NUMBER: NCT05685693 (clinicaltrials.gov).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。