Association between imaging parameter changes and triangular fibrocartilage complex injury after distal radius fractures

桡骨远端骨折后影像学参数变化与三角纤维软骨复合体损伤的相关性

阅读:1

Abstract

BACKGROUND: Triangular fibrocartilage complex (TFCC) injury is a frequent soft tissue injury that has been observed to accompany distal radius fractures (DRFs) with concomitant changes in radiologic parameters. The aim of this study was to investigate the relevance of distal radial radiologic parameters associated with DRF and traumatic TFCC injury. METHODS: A total of 172 patients with distal radius fractures who underwent X-ray, CT, and MRI before undergoing volar locking plate or external splint fixation between October 2021 and December 2022 were included in this study. An analysis of various radiologic parameters and the classification of fracture type and TFCC injuries by CT and MRI was performed. All patients were divided into the TFCC uninjured group and the injured group. The incidence and relevant radiologic parameters were compared. RESULTS: This study included 76 males and 96 females with a mean age of 56.1 years. Among all patients, 33 (19.2%), 40 (23.2%), and 99 (57.6%) had DRF with A, B, and C fractures, respectively, according to the AO/OTA classification. In patients with fractures, the TFCC was found to be injured in 54.1% (93/172) of patients (type 1A in 21, 1B in 46, 1C in 39, and 1D in 35) but uninjured in 45.9% (79/172). There were significant differences between the TFCC injured and uninjured groups regarding the radius length (p = 0.044) and DRUJ distance (p = 0.040) of radiologic parameters that changed with DRF, although there were no differences between the two groups regarding gender, age, injured side, intra- and extra-articular, radius inclination and palmer tilt angle, or sagittal translation. Within the TFCC injured group, the radius length and DRUJ distance were 4.83 mm and 2.95 mm less or wider than 7.19 mm and 1.83 mm of the uninjured group. Moreover, shorter radius length was related to type lB TFCC injury (p = 0.041). Both radius length (AUC = 0.658) and DRUJ distance (AUC = 0.582) had no convincing predictive value for TFCC injury in DRF. CONCLUSION: 1B TFCC injury is most common in patients with DRF and concomitant TFCC injury. Both radius length and DRUJ distance have a significant statistical correlation with TFCC injury, and patients with TFCC injury tend to have a shortened radius and wider DRUJ distance, although they have no predictive value for TFCC injury in DRF. In addition, a shorter radius length was related to type lB TFCC injury.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。