Three-dimensional femur morphology analysis for the optimal location of subtrochanteric osteotomy with an implanted Wagner cone stem in total hip arthroplasty for Crowe type IV developmental dysplasia of the hip

对 Crowe IV 型发育性髋关节发育不良患者进行全髋关节置换术,并植入 Wagner 锥形柄,通过三维股骨形态分析确定股骨转子下截骨的最佳位置。

阅读:2

Abstract

BACKGROUND: This study aimed to accurately evaluate the matching of proximal and distal femoral segments and fitting of the femur-femoral stem in patients with Crowe type IV developmental dysplasia of the hip (DDH) who have undergone subtrochanteric osteotomy at different locations with an implanted Wagner cone stem to improve the rate of the bone union at the osteotomy site. METHODS: Three-dimensional femur morphology of 40 patients with Crowe type IV DDH was evaluated at each cross-section to determine the femoral cortical bone area. This study focused on five osteotomy lengths (2.5, 3, 3.5, 4, and 4.5 cm). The overlapped area between the proximal and distal cortical bone segments was defined as the contact area (S, mm(2)), and the contact area to distal cortical bone area ratio was defined as the coincidence rate (R). Three indicators were used to evaluate the matching and fitting of the osteotomy sites with the implanted Wagner cone stems: (1) higher S and R between the proximal and distal segments; (2) the effective fixation length of the femoral stem at the distal segments being at least 1.5 cm; and (3) osteotomy did not involve the isthmus. RESULTS: In all groups, S significantly decreased in the two proximal levels above the 0.5 cm level below the lesser trochanter (LT) compared with those below this level. In comparison, at osteotomy lengths from 2.5 to 4 cm, R significantly decreased in the three proximal levels. The optimal osteotomy levels ranged from 1.5 and 2.5 cm below the LT for an appropriately sized stem. CONCLUSIONS: Subtrochanteric osteotomy at the optimal level not only ensures fitting of the femur-femoral stem but also meets the requirements of a higher S and R to ensure adequate reduction and stabilization at the osteotomy site, which may contribute to the bone union. Although the optimal osteotomy level varies with the size of the femoral stem and the length of the subtrochanteric osteotomy, the optimal osteotomy levels for an appropriately sized Wagner cone femoral stem implantation range from 1.5 to 2.5 cm below the LT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。