Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study

机器人辅助经皮三角骨合成术治疗垂直不稳定骶骨骨折:单中心回顾性研究

阅读:1

Abstract

BACKGROUND: To evaluate the effectiveness and safety of robot-aided percutaneous triangular osteosynthesis combined with close reduction for vertically unstable sacrum fractures (VUSFs). METHODS: The data on 21 patients of the VUSF were retrospectively analyzed from November 2016 to January 2021. According to Denis classification, there were 3 cases in zone I, 11 cases in zone II, and 7 case in zone III. The main perioperative indicators were recorded. The maximal angulation and displacement deviations of the screws were analyzed by comparing the planned trajectory with the actual position. Postoperative X-ray radiographs and CT scans were obtained for evaluating the reduction quality. Functional outcome was scored with Majeed criterion. RESULTS: Fourteen patients of the unilateral VUSF and 7 patients of the bilateral VUSF underwent unilateral and bilateral triangular osteosynthesis with robotic assistance, respectively. No intraoperative neurovascular injuries and postoperative infection occurred. All patients were followed up for at least 12 months. The average operation time of posterior pelvic ring was 111.4 min, with the mean intraoperative bleeding of 110.5 ml. A total of 58 pedicle and iliosacral screws were implanted with robotic assistance. Of those, 52 screws were in the cancellous bone except 4 pedicle and 2 iliosacral screws cutting the cortical bone. The angulation and displacement deviations of the screws were 4.2° ± 2.5° and 1.7 ± 0.9 mm, respectively. The average displacement of the sacral fracture was reduced from 19.7 mm preoperatively to 3.1 mm postoperatively. According to Matta's criterion, the reduction quality was graded as "excellent" in 13 patients and "good" in 8. All sacral fractures healed within 6 months except one fracture with nonunion. The mean Majeed score at the last follow-up was 89.6. CONCLUSIONS: Robot-aided triangular osteosynthesis combined with close reduction provide a safe and reliable option for percutaneous treatment of the fresh VUSF, with a high accuracy of iliosacral and pedicle screw implantation except insertion of iliac screws. Meanwhile, the technique may help to reduce incision-related complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。