Femoral periprosthetic fracture treatment using the Ortho-Bridge System: a biomechanical study

采用Ortho-Bridge系统治疗股骨假体周围骨折:一项生物力学研究

阅读:1

Abstract

BACKGROUND: We undertook a comparative biomechanical study of type B1 fractures around femoral prostheses following cemented hip arthroplasty using the Ortho-Bridge System (OBS) and a locking compression plate/locking attachment plate structure (LCP + LAP). We aimed to investigate the biomechanical characteristics and advantages of the OBS compared with LCP + LAP when treating this fracture type. METHODS: An OBS fixation model was designed based on OBS and LCP + LAP fixation characteristics. The LCP + LAP combination (Group A) and three different OBS combinations (Groups B, C, and D) were used to fix a B1 fracture model with a femoral periprosthetic fracture. Axial compression and torsion experiments were then performed using simple and comminuted fracture models. The axial compression failure experiment was carried out, and the model stiffness during axial compression, torsion angle in torsion test, and vertical load in the final failure test were collected. RESULTS: When simulating simple oblique fractures, no significant difference was found among the four groups in terms of stiffness in the axial compression experiment (P = 0.257). The torsion angle of the LCP + LAP system was significantly higher compared with the OBS system (P < 0.05). When simulating a comminuted fracture, the experimental data for axial compression showed that the rigidity measurements of the three combinations of the OBS system were higher compared with the LCP + LAP system (P = 0.000) and that the torsion angles of three combinations of the OBS system were smaller compared with the LCP + LAP system (P < 0.05). In the axial compression failure test, the fixed failure mode of the LCP + LAP system was the destruction of the contact cortex at the fracture site, whereas the failure modes in the three OBS combinations involved fracture around the screws above the osteotomy and destruction of the contact cortex at the fracture site. CONCLUSIONS: The findings revealed that the OBS produced superior biomechanical outcomes compared with LCP + LAP, especially for the bridging two-rod dual cortex. According to the performance observed after model axial compression destruction, the OBS was fixed and provided greater stress dispersion, which might make it more suitable for facilitating early functional movement and avoiding the failure of internal fixation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。