Freehand transperineal prostate biopsy with a coaxial needle under local anesthesia: Experience from a single institution in Malaysia

马来西亚某机构在局部麻醉下使用同轴针进行徒手经会阴前列腺活检:经验总结

阅读:3

Abstract

BACKGROUND: Freehand transperineal prostate biopsy (TPPBx) using a coaxial needle technique offers an alternative to probe-mounted freehand or template-guided techniques in the diagnosis of prostate cancer (PCa). It only requires the same equipment used for transrectal ultrasound-guided (TRUS) biopsy. Our study is the first in Malaysia to report this experience and its outcomes. We aim to determine PCa detection rate and pain tolerability of freehand TPPBx utilizing a coaxial needle under local anesthesia (LA). METHODS: Institutional review board approval was obtained from National Medical Research Register (NMRR ID-21-02052-VIL). We retrospectively reviewed the medical records of patients who underwent TPPBx between August 2020 and April 2022. Records were reviewed for patients' characteristics, prostate volume, prostate-specific antigen (PSA) results, biopsy results and pain tolerability. Data was analyzed to determine PCa and clinically significant prostate cancer (csPCa) detection rate. LA was achieved using perineal skin infiltration and a periprostatic nerve block. The commonly used standard side-firing transrectal ultrasound with its Prostate Biplane Transducer was used as an imaging guide. The principles of the Ginsburg protocol were followed. Pain tolerability was assessed using a visual analog scale. RESULTS: A total of 55 patients with elevated PSA levels underwent freehand TPPBx under LA. The mean age was 67.3 years, the median PSA was 14.2 ng/mL, and the median PSA density (PSAD) was 0.33 ng/mL/cc. The optimal PSAD cutoff for predicting csPCa was 0.35 ng/mL/cc (area under the curve [AUC], 0.792; sensitivity, 87.5%; specificity, 69.2%). PCa was detected in 24 patients (43.6%), of whom 16 (29.1%) had csPCa. The median pain scores during LA infiltration and biopsy were four and two, respectively, which were significant different (P < 0.05). TPPBx exhibited an infection rate of zero. CONCLUSION: The PCa detection rate and patient tolerability of freehand TPPBx using a coaxial needle are similar to those of a contemporary published series. The use of existing equipment that is used for TRUS biopsy allows for widespread use and transition from TRUS biopsy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。