Transcervical minimally invasive esophagectomy: hemodynamic study on an animal model

经颈微创食管切除术:动物模型血流动力学研究

阅读:1

Abstract

BACKGROUND: Transcervical esophagectomy is a less invasive procedure performed within mediastinum. However, the mediastinum offers limited surgical space and the surgery via this route differs from conventional minimally invasive esophagectomy. Therefore, the physiological study of this surgical approach on an animal model would be necessary before the procedure gained more popularity. METHODS: We conducted transcervical minimally invasive esophagectomy on animal model (swine) under CO(2) pneumomediastinum. The hemodynamic parameters were monitored using float catheter cannulated via right jugular vein. At different anatomical level (the upper, middle, and lower thoracic part of the animal esophagus), increased artificial pneumomediastinal pressures (0, 4, 8, 12, and 16 mmHg) were consecutively allocated to record the intra-operative changes of blood pressure, cardiac output (CO), central venous pressure (CVP), pulmonary artery pressure (PAP) and extravascular lung water (EVLW). Meanwhile, the surgical field under different pneumomediastinum pressure was recorded and balanced with animals' hemodynamic changes to determine the optimal pressure for transcervical minimally invasive esophagectomy. RESULTS: The animal procedures were accomplished without conversions. During the upper thoracic stage, increased CO(2) pressures did not lead to significant changes in hemodynamic parameters including the blood pressure, CO, CVP, PAP or the level of EVLW. During the middle thoracic stage, pneumomediastinum under 4-12 mmHg did not lead to significant changes in hemodynamic parameters. However, pneumomediastinum at 16 mmHg resulted in lower CO (P=0.038) when compared to 0-12 mmHg. During lower thoracic stage, as the pneumomediastinum pressures increased from 0 to 16 mmHg, significant decrease in CO (P=0.022), and increase in CVP (P=0.036) was recorded. In compared to 4 mmHg pneumomediastinum, the surgical field under 8-16 mmHg artificial CO(2) pneumomediastinum was suitable for mediastinal manipulation. CONCLUSIONS: During transcervical minimally invasive esophagectomy on animal model, the mobilization of swine thoracic esophagus with optimal pneumomediastinum pressure 8-12 mmHg is safe and effective based on hemodynamic analysis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。