Comparison of blood flow in single and sequential vein grafts during off-pump coronary artery bypass

在非体外循环冠状动脉旁路移植术中,单根静脉移植和序贯静脉移植的血流比较

阅读:1

Abstract

BACKGROUND: The use of sequential anastomoses in coronary artery bypass grafting (CABG) is still controversial. This study aimed to evaluate the mean blood flow (MBF) rate and pulsatility index (PI) of single and sequential saphenous vein grafts to the posterior descending artery (PDA) in the same patient during off-pump CABG (OPCABG). METHODS: Sequential saphenous vein grafts were used to bypass the diagonal artery (Diagonal) (side-by-side), obtuse marginal artery (OM) (side-by-side) and PDA (end-to-side). The anastomoses of Diagonal and OM were temporarily occluded with bulldog clamps, making the sequential graft a "single" graft to PDA. The MBF and PI of this "single" graft to PDA were measured with transit-time flow measurement (TTFM). Then the bulldog clamps were removed and the MBF and PI of sequential graft to PDA were measured again and compared to those of the "single" graft in the same patient. Anastomoses were evaluated with coronary CT angiogram at 6 months. RESULTS: A total of 128 patients with triple vessel disease were enrolled (96 men; mean age, 66.0±8.0 years; range, 54-80 years). The MBF of the "single" vs. sequential graft to PDA was 20.6±9.1 vs. 21.4±10.1 mL/min (P=0.472). The PI of 'single graft' vs. sequential graft to PDA was 1.7±0.6 vs. 1.7±0.5 (P=0.941). The patency of all grafts was good in all patients after 6 months of follow-up. CONCLUSIONS: There were no hydrodynamic differences between single and sequential grafts to PDA in OPCABG.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。