Mid-term follow-up after suture-less aortic heart valve implantation

无缝线主动脉瓣膜植入术后中期随访

阅读:1

Abstract

BACKGROUND: Aortic stenosis (AS) is the most common valve disease in the adult population and its prevalence increases with age. Unfortunately, older age and comorbidities significantly increase mortality, operative risk and worsen prognosis. In recent years, sutureless bioprosthesis [sutureless-aortic valve replacement (SU-AVR)] has become an alternative to standard AVR or TAVI in high-risk patients. Compared to standard AVR, the advantages of SU-AVR include shorter valve implantation, shorter aortic cross clamp (ACC) and cardiopulmonary bypass (CPB) times and higher valve EOA with more favorable hemodynamic parameters. Good early clinical and hemodynamic outcomes have been reported in several studies. However, although early SU-AVR results reported in the literature are encouraging, there are few results of long term follow-up. The aim of this study is to present long term echocardiographic hemodynamic outcomes of the Enable sutureless bioprosthesis. METHODS: The first human implantation of the Enable sutureless bioprosthesis was performed on the 13th January, 2005 by the authors of this manuscript. From that time until July 2008, 25 patients underwent isolated SU-AVR implantation. The median preoperative logistic EuroSCORE was 1.92±0.17 [standard deviation (SD)] and the STS score was 2.96±2.73. Preoperatively, 65.4% of patients were in NYHA class III or IV, the peak/mean gradient transaortic gradient was 84.6/52.1 mmHg. RESULTS: After the SU-AVR procedure, the average peak/mean aortic gradients were respectively: 12.9/7.1 mmHg at the intraoperative time; 18.1/9.5 mmHg at 3-6 months; 18.3/9.6 mmHg at 11-14 months; 16.9/9.3 mmHg at 2 years; 15.3/8 mmHg at 3 years; 13.4/7.1 mmHg at 4 years; 16.7/8.9 mmHg at 5 years follow-up. Other hemodynamic echocardiographic parameters such as LVOT diameter, LVOT peak velocity, LVOT TVI, valve peak velocity and valve TVI were stable during the follow-up period. CONCLUSIONS: In summary, sutureless bioprostheses are safe and effective treatments for valve stenosis with excellent outcomes and hemodynamic profile which remained stable during the follow-up period. The peak and mean gradients were 16.7 and 8.9 mmHg, respectively, over a 5-year follow-up period.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。