Complications related to endoscopic lung volume reduction for emphysema with endobronchial valves: results of a multicenter study

内镜下肺减容术治疗肺气肿伴支气管内瓣膜相关并发症:一项多中心研究的结果

阅读:1

Abstract

BACKGROUND: Despite bronchoscopic lung volume reduction (BLVR) with valves is a minimally invasive treatment for emphysema, it can associate with some complications. We aimed at evaluating the rate and type of complications related to valve treatment and their impact on clinical outcomes. METHODS: It is a retrospective multicenter study including all consecutive patients with severe heterogeneous emphysema undergoing BLVR with endobronchial valve treatment and developed any complications related to this procedure. The type of complication, the time of onset, the treatment required and the out-come were evaluated. Response to treatment was assessed according to the minimal clinically important difference (MCID) as follows: an improvement of ≥15% in forced expiratory volume in one second (FEV(1)); of -8% in residual volume (RV); of ≥26 m in 6-minnute walking distance (6MWD); and of ≥4 points on the St. George's Respiratory Questionnaire (SGRQ). Target lobe volume reduction (TLVR) ≥350 mL was considered significant. RESULTS: One hundred and seven out of 423 (25.3%) treated patients had complications related to valve treatment including pneumothorax (17.3%); pneumonia (1.7%), chronic obstructive pulmonary disease (COPD) exacerbation (0.9%), respiratory failure (1.4%), valve migration (2.1%), and hemoptysis (1.9%). In all cases complications resolved with appropriate treatment including removal of valves in 21/107 cases (19.6%). Patients with TLVR ≥350 mL (n=64) vs. those <350 mL (n=43) had a statistically significant higher improvement in FEV(1) (19.0%±3.9% vs. 3.0%±0.9%; P=0.0003); in RV (-10.0%±4.8% vs. -4.0%±2.9%; P=0.002); in 6MWD (33.0±19.0 vs. 12.0±6.3 metres; P=0.001); and in SGRQ (-15.0±2.9 vs. -8.0±3.5 points; P=0.01). Only patients with TLVR ≥350 mL met or exceeded the MCID cut-off criteria for FEV(1) (19.0%±3.9%), RV (-10.0%±4.8%), 6MWT (33.0±19.0 metres), and SGQR (-15.0±2.9 points). Five patients (1.2%) died during follow-up for causes not related to valves treatment neither to any of the complications described. CONCLUSIONS: Valve treatment is a safe and reversible procedure. The presence of complications seems not to have a significant impact on clinical outcome in patients with lobar atelectasis. Due to poor clinical conditions and possible complications, BLVR should be performed in high volume centers with a multidisciplinary approach.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。