A Simple Molecular Tool for the Assessment of Kidney Transplant Biopsies

用于评估肾移植活检的简单分子工具

阅读:8
作者:Tristan de Nattes, Jack Beadle, Frederic Toulza, Edvin Candon, Philippe Ruminy, Arnaud François, Dominique Bertrand, Dominique Guerrot, Fanny Drieux, Candice Roufosse, Sophie Candon

Background

The Banff Classification for Allograft Pathology recommendations for the diagnosis of kidney transplant rejection includes molecular assessment of the transplant biopsy. However, implementation of molecular tools in clinical practice is still limited, partly due to the required expertise and financial investment. The reverse transcriptase multiplex ligation-dependent probe amplification (RT-MLPA) assay is a simple, rapid, and inexpensive assay that permits simultaneous evaluation of a restricted gene panel using paraffin-embedded tissue blocks. The

Conclusions

The 17-gene panel RT-MLPA assay, developed here for formalin-fixed paraffin-embedded kidney transplant biopsies, classified kidney transplant rejection with an overall accurate prediction ratio of 0.83. Podcast: This article contains a podcast at https://dts.podtrac.com/redirect.mp3/www.asn-online.org/media/podcast/CJASN/2023_04_10_CJN10100822.mp3.

Methods

A retrospective cohort of 220 kidney transplant biopsies from two centers, which included 52 antibody-mediated rejection, 51 T-cell-mediated rejection, and 117 no-rejection controls, was assessed. A 17-gene panel was identified on the basis of relevant pathophysiological pathways. A support vector machine classifier was developed. A subset of 109 biopsies was also assessed using the Nanostring Banff Human Organ Transplant panel to compare the two assays.

Results

The support vector machine classifier train and test accuracy scores were 0.84 and 0.83, respectively. In the test cohort, the F1 score for antibody-mediated rejection, T-cell-mediated rejection, and control were 0.88, 0.86, and 0.69, respectively. Using receiver-operating characteristic curves, the area under the curve for class predictions was 0.96, 0.89, and 0.91, respectively, with a weighted average at 0.94. Classifiers' performances were highest for antibody-mediated rejection diagnosis with 94% correct predictions, compared with 88% correct predictions for control biopsies and 60% for T-cell-mediated rejection biopsies. Gene expression levels assessed by RT-MLPA and Nanostring were correlated: r = 0.68, P < 0.001. Equivalent gene expression profiles were obtained with both assays in 81% of the samples. Conclusions: The 17-gene panel RT-MLPA assay, developed here for formalin-fixed paraffin-embedded kidney transplant biopsies, classified kidney transplant rejection with an overall accurate prediction ratio of 0.83. Podcast: This article contains a podcast at https://dts.podtrac.com/redirect.mp3/www.asn-online.org/media/podcast/CJASN/2023_04_10_CJN10100822.mp3.

特别声明

1、本文转载旨在传播信息,不代表本网站观点,亦不对其内容的真实性承担责任。

2、其他媒体、网站或个人若从本网站转载使用,必须保留本网站注明的“来源”,并自行承担包括版权在内的相关法律责任。

3、如作者不希望本文被转载,或需洽谈转载稿费等事宜,请及时与本网站联系。

4、此外,如需投稿,也可通过邮箱info@biocloudy.com与我们取得联系。