Replenishing a computerized adaptive test of patient-reported daily activity functioning

补充计算机化自适应测试,用于评估患者自述的日常活动功能

阅读:1

Abstract

PURPOSE: Computerized adaptive testing (CAT) item banks may need to be updated, but before new items can be added, they must be linked to the previous CAT. The purpose of this study was to evaluate 41 pretest items prior to including them into an operational CAT. METHODS: We recruited 6,882 patients with spine, lower extremity, upper extremity, and nonorthopedic impairments who received outpatient rehabilitation in one of 147 clinics across 13 states of the USA. Forty-one new Daily Activity (DA) items were administered along with the Activity Measure for Post-Acute Care Daily Activity CAT (DA-CAT-1) in five separate waves. We compared the scoring consistency with the full item bank, test information function (TIF), person standard errors (SEs), and content range of the DA-CAT-1 to the new CAT (DA-CAT-2) with the pretest items by real data simulations. RESULTS: We retained 29 of the 41 pretest items. Scores from the DA-CAT-2 were more consistent (ICC = 0.90 versus 0.96) than DA-CAT-1 when compared with the full item bank. TIF and person SEs were improved for persons with higher levels of DA functioning, and ceiling effects were reduced from 16.1% to 6.1%. CONCLUSIONS: Item response theory and online calibration methods were valuable in improving the DA-CAT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。