A Novel Approach for the Retrieval of Broken Catheter Fragment - Using Balloon Dilatation Technique

一种取出断裂导管碎片的新方法——球囊扩张技术

阅读:1

Abstract

In this era of an ever increasing number of interventions in cardiology, there is a parallel increase in the number of complications associated with these interventions, such as broken catheter tip and guide wire embolisation. The most commonly used and effective method for the percutaneous retrieval of such broken fragments is a goose neck snare. However in cases where this technique has been a failure, newer and novel innovations have been implemented for the retrieval of such broken fragments. We present a case of seven-year-old female child with a 3mm peri-membranous ventricular septal defect who was taken up for device closure. During the procedure the internal mammary catheter was broken in the left ventricle and subsequently the broken fragment was embolised to the left common carotid artery. The broken fragment was snared down upto the common iliac but could not be retrieved out of the sheath. A novel approach was used, consisting of negotiating a coronary guide wire across the broken catheter and inflating a balloon in the catheter fragment which helped to achieve a co-axial alignment with the arterial sheath and hence by which it was possible to retrieve the broken catheter fragment out of the circulatory system.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。