Performance evaluation and clinical application of the UA-5600 automatic dry chemistry urine analyzer in renal diseases

UA-5600全自动干式尿液化学分析仪在肾脏疾病中的性能评价及临床应用

阅读:1

Abstract

BACKGROUND: Urine testing as a routine screening programme, abnormal test results can be suggestive to clinicians but can sometimes be overlooked, and the establishment of a diagnostic model can better assist clinicians in identifying potential problems. BLD (blood), LEU (leukocyte), PRO (protein) and GLU (glucose) are the four most important parameters in urine testing, and the accuracy of their results is a key concern for clinicians, so it is essential to verify the accuracy of their results. In this study, we evaluated the analytical and clinical performance of Mindray's automatic urine dry chemistry analyzer, the UA-5600 (Hereinafter referred to as the (UA-5600), and the test strips configured with the instrument, and developed a machine-learning (ML) model for kidney disease screening from the results of 11 parameters output from the UA-5600 with the aim of detecting abnormal urine test results. METHODS: Urine samples from outpatients and inpatients at The First Affiliated Hospital of Sun Yat-sen University were collected from August to September 2022 to evaluate the performance of the Mindray UA-5600 dry chemistry analyzer and test strips. The evaluation of the UA-5600 and its test strips focused on the agreement of the urine BLD and LEU readings with the RBC (red blood cell) and WBC (white blood cell) counts obtained by the Mindray EH-2090 urine formed element analyzer. We also compared the PRO and GLU readings with the results of the Mindray BS-2800M biochemistry analyzer. Urine samples from outpatients and inpatients were retrospectively analysed and grouped according to LIS diagnosis. Additionally, eight ML models for kidney disease screening were developed using 11 parameters measured by the UA-5600. And the model was validated by the validation set. RESULTS: The UA-5600 had an 89.55% concordance rate for BLD and a 91.04% concordance rate for LEU compared to the EH-2090 analyzer. When benchmarked against the BS-2800M, the concordance rates for PRO and GLU were 94.14% and 95.20%, respectively. A total of 1,691 samples were used for the construction of the ML models, of which 346 patients (135 males and 211 females, age range: 18 to 98 years) diagnosed with renal disease, and 1,345 patients (397 males and 948 females, age range: 18 to 92 years) with non-renal disease diagnosed with other conditions. Notably, the Naïve Bayes (NB) model, which was built from the UA-5600 parameters, demonstrated superior predictive capabilities for renal disease, with an area under the receiver operating characteristic curve of 0.9470, a sensitivity of 0.7767, and a specificity of 0.9457. CONCLUSIONS: The Mindray UA-5600 demonstrates robust detection abilities for both BLD and LEU, and its results for PRO and GLU align closely with those obtained from the chemistry analyzer. The NB model has a good screening ability and shows promise as an effective screening tool.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。