A case report of right cardiac ventricle perforation by uncontrolled embolization coil inserted for treating penile veno-occlusive dysfunction

一例因治疗阴茎静脉闭塞功能障碍而植入的栓塞线圈失控导致右心室穿孔的病例报告

阅读:1

Abstract

Coil embolization (CE) is believed effective-safe for treating penile veno-occlusive dysfunction (VOD). From 2012 to 2016, refractory impotence prompted four men to seek further treatment, although they underwent six CEs elsewhere. Uncontrolled coils scattered along penile drainage veins including the deep dorsal veins (n = 3), periprostatic plexus (n = 1), iliac vein (n = 1), right pulmonary artery (n = 2), left pulmonary artery (n = 1), and right ventricle (n = 1). The last one occurred in a 40-year-old house builder, and the coil perforated the right ventricle wall and diaphragm 18 months later. Given no sustainable improvement, CE's safety and efficacy are unreliable for treating patients with VOD.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。