[Determination of two quaternary ammonium salts in disinfector by portable capillary electrophoresis device based on smartphone]

[基于智能手机的便携式毛细管电泳装置测定消毒剂中两种季铵盐]

阅读:1

Abstract

The existing miniature capillary electrophoresis (CE) devices use a tablet or a computer for data processing and analysis, which hinders their portability. In order to solve this problem, a smartphone-based CE device was proposed, which allowed for real portable quantitative analysis. The device integrated the functions of capacitively coupled contactless conductivity detection (C(4)D) and Bluetooth communication. Furthermore, a Kotlin language-based application with a user-friendly interface was developed. The application could not only control the electrophoresis run in the CE device but also receive the data from the C(4)D detector in real time, display the electrophoretogram, and process the data. The peak areas could be calculated automatically on the smartphone, and the migration time could be obtained. The size of the developed device was 20 cm×20 cm×15 cm, and its weight was 2 kg. Quaternary ammonium salts (QAs) in disinfectors (dodecyl dimethyl benzyl ammonium bromide (DDBAB) and dodecyl trimethyl ammonium bromide (DTAB)) were used as the analytes to verify the performance of the developed device. The experimental data showed that the linear ranges of DDBAB and DTAB were from 20 to 1000 and from 30 to 1000 μmol/L, respectively. The correlation coefficients (R(2)) of DDBAB and DTAB were 0.9995 and 0.9989, respectively, indicating good linearity between the peak area and concentration. The limits of detection (LODs) of DDBAB and DTAB were 10 and 13 μmol/L, respectively. The intra-day relative standard deviations (RSDs, n=3) of DDBAB and DTAB were 1.9% and 2.7% respectively, revealing good repeatability. In addition, a mixture of DDBAB and DTAB was tested. Two QAs were separated within 8 min, showing good selectivity. Finally, QAs in a bromo geramine disinfector used in the field were tested to further validate the performance of the designed device. The recoveries of DDBAB and DTAB were 100.5%-101.5% and 96.2%-99.3%, respectively, indicating good accuracy. The developed device has the advantages of good linearity, low LOD, good repeatability, high accuracy, and real portability, and it can be used for the quantitative detection of QAs in disinfectors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。